CHAMBER 4-COMPS

Four sample compartments.
One controlled testing platform.

Chamber 4X combines four glass-covered compartments with custom temperature-controlled fixtures for parallel sample testing. Air or nitrogen connections and electrical interfaces bring atmosphere management, sample signals and thermal control into one compact assembly.

  • Four compartments
  • 15–80 °C cell temperature
  • Air or nitrogen
  • Custom thermal fixtures
Chamber 4X with four circular glass covers, hand-tightened knobs and front electrical connectors
Chamber 4X with four individually accessible sample compartments.

Each compartment combines a glass cap, sealed casing and a custom temperature-controlled fixture. The four-position layout supports comparative experiments while allowing the sample holders and contacts to be configured for the devices under test.

TECHNICAL DETAILS

Controlled conditions at each sample position.

Compartments
4, approximately 0.2 L each
Cell temperature control
+15 to +80 °C
Operating ambient temperature
+15 to +30 °C
Process gases
Air or nitrogen
Operating gauge pressure
0 to +0.1 bar
Maximum admissible gauge pressure
+0.2 bar; not an operating setpoint
Approximate weight
3.5 kg
Electrical interface
44-pin DUT/TEC connectors

Specifications refer to the CHAMX4 user guide, revision 2, February 2020. Fixture and connection details depend on the supplied configuration.

Gas routing and measurement connections.

Configurable gas connections

Each compartment has two 1/8 BSP threaded ports, supplied as standard with one tube fitting and one plug. The gas setup uses 6 mm tubing with external inlet and outlet valves.

Internal channels link compartments 1–2 and 3–4. These pairwise connections can be isolated using 1/8 BSP plugs as described in the user guide.

Sample and thermal interfaces

The 44-pin DUT/TEC connectors carry sample signals and temperature-control connections. Custom fixtures provide the thermal contact and electrical contact arrangement required by the device.

Glass caps locate on alignment pins and are secured with hand-tightened knobs. Clean seals, correct fixture positioning and even tightening support reliable closure.

Use in a ventilated indoor laboratory. Route nitrogen outlets to a suitable gas exhaust and follow the user guide for connection, purging and opening procedures. Avoid sudden pressure changes; glass covers can become hot during operation.

INTEGRATION EXAMPLE

Four controlled positions in one experimental platform.

This configuration shows the four-compartment chamber hardware integrated with gas and pressure lines in a real test setup. The architecture can be adapted around the required sample holders, fluidic connections and environmental-control workflow.

Chamber 4-comps integrated with gas and pressure lines in a test setup
Example Chamber 4-comps integration with external gas and pressure connections.